Hello everyone, I am pulling my home’s existing ethernet cables from the garage and into my home to install a network rack. Currently my garage does not have insulation (for a future project), so it get’s too hot during summer for my router to live there, so I want to install it in my mudroom where there is insulation. My question is if I drill a hole to put some sort of cable cover (ie. https://a.co/d/1hHosME) will it affect my home’s insulation too much where I should be doing something else? If so, what should I do to improve the cable runs?

  • agegamon@beehaw.org
    link
    fedilink
    arrow-up
    5
    ·
    edit-2
    1 year ago

    If you are looking for a permanent cable run, rather than those fuzzy-brush covers (which have zero insulation or fire-block potential) you can get in-wall ethernet wall plate ports that will seal air out and provide a permanent ethernet receptacle in the wall. The advantage of these is that once you install them, you can disconnect the cable from either side of the wall if necessary, rather than having to snake the cable back out of the the wall again. In your case, even if you’re just going from one side of the wall to the other, this is worth doing if the cable would stay there permanently or if you plan to pipe Ethernet in even after moving the modem to the garage later (not that I recommend that - just keep it inside if you can).

    https://www.homedepot.com/p/Commercial-Electric-Category-6-Jack-in-White-10-Pack-5016-WH-10PK/305193884

    https://www.homedepot.com/p/Commercial-Electric-White-1-Gang-1-Decorator-Rocker-1-Duplex-Wall-Plate-1-Pack-5001-WH/206428112

    If you use foam to fill any voids or gaps around the cable, make sure you use fire-blocking foam inside the wall (can get it at any hw store). It’s required by code in some areas, better safe than sorry. This is for inside the wall, i.e. you don’t want to see it because it’s typically a bright orange color.

    I recommend you use a shielded and outdoor-rated Ethernet cable if possible to cut down on interference. Most good quality cables now are shielded, but wanted to mention just in case.

    • HurlingDurling@lemm.eeOP
      link
      fedilink
      English
      arrow-up
      2
      ·
      1 year ago

      Thanks, but I actually need to run 10 cables to the garage. I think you can do upto 6 one one plate correct?

      • agegamon@beehaw.org
        link
        fedilink
        arrow-up
        1
        ·
        edit-2
        1 year ago

        Yeah, the most I’ve ever seen is six on a single plate. I wouldn’t go that route either.

        Honestly if it was me I’d just make one or two runs through the wall and add a network switch on whichever side needs 10 runs. But if you need 10 separate runs then I’d throw a larger piece of conduit through the wall next to a stud, anchor it, make it look nice on either side, and shove some fire-block or some loose foam in (not sure if loose foam is to code but I hate fire-block spray foam so much lol) to keep air from flowing. Pretty much exactly what you originally planned honestly.

        There are downward-facing hoods that IMO are a little prettier than the fuzzy wall plates, but if those don’t bother you then that’s probably fine.

  • 14th_cylon@lemm.ee
    link
    fedilink
    arrow-up
    5
    ·
    1 year ago

    the smaller the hole, the smaller the heat transfer. you can also fill it with some kind of montage foam, once the cables are through.

  • rekabis@programming.dev
    link
    fedilink
    arrow-up
    3
    ·
    1 year ago

    Passing cables through existing walls nearly always involves taking part of the drywall off to gain access to the core of the wall. If you need to feed a wire across an entire wall, you typically have to cut an entire strip of drywall off along the entire length of the wall.

    If you have access to the beams beneath the floor or in the ceiling, you may want to do most of the run there, then drill into the desired wall through the sill or header plate. That allows you to get the cable into a specific stud gap to limit the amount of drywall affected.

    But unless your house was built with cable pipes/runs built into it (and I can’t imagine this being done outside of commercial buildings), you have lots of futzing around to do, and no small amount of drywall work.

    • HurlingDurling@lemm.eeOP
      link
      fedilink
      English
      arrow-up
      2
      ·
      1 year ago

      It’s actually drywall on both sides with no firewall but one side is the garage which is not insulated, so there’s insulation on the wall I will be running the cables through, which will be done horizontally

  • nyan@lemmy.cafe
    link
    fedilink
    English
    arrow-up
    1
    ·
    1 year ago

    If the garage is too hot for your router, it probably isn’t the best place for your network and/or server gear either. Unless you’re intending to water-cool it.

    (To put it another way, are you absolutely sure you’ve thought this through and there is no small-network-rack-sized space in the house? Under the stairs, in the back of a closet, or on top of a cabinet, maybe?)

    • HurlingDurling@lemm.eeOP
      link
      fedilink
      English
      arrow-up
      1
      ·
      1 year ago

      There isn’t all the cables terminate outside the house on the outer wall for the garage. It was like that when it was built.